Hash 2100AN laboratory turbidity meter

Hash 2100AN laboratory turbidity meter

The programmable signal averaging function, instrument automatic calibration function, and built-in printer printing function of the Hach Laboratory Turbidimeter 2100AN in the United States have greatly optimized the tes···...
Get a quote →
Details


The programmable signal averaging function, instrument automatic calibration function, and built-in printer printing function of the Hach Laboratory Turbidimeter 2100AN in the United States have greatly optimized the test process and facilitated data management;

The ratio measurement mode developed using Hach's patented technology effectively ensures the elimination of chromatic interference; the sensitive fault self-diagnosis function can promptly remind users to discover and eliminate instrument faults;

Air can be introduced into the sample test chamber to purge it,  prevent light scattering caused by water vapor condensation, so it is suitable for measuring the turbidity of cold and hot water samples.
The instrument has a data storage function, and the experimental data can be directly downloaded to the computer through the HachLinkTM software, which is convenient for data storage and management.

The built-in printer can directly print the measurement results and related parameters.

Features and Advantages

The instrument has programmable signal averaging function, instrument automatic calibration function, built-in printer printing function, etc., which greatly optimizes the test process and facilitates data management;

The ratio measurement mode developed by Hach's patented technology effectively ensures the elimination of chromatic interference; the sensitive fault self-diagnosis function can promptly remind users to discover and eliminate instrument faults;

Air can be introduced into the sample test chamber to purge it,  prevent light scattering caused by water vapor condensation, so it is suitable for measuring the turbidity of cold and hot water samples.
The instrument has a data storage function, and the experimental data can be directly downloaded to the computer through the HachLinkTM software, which is convenient for data storage and management.

The built-in printer can directly print the measurement results and related parameters.

 

Technical Parameters

Standard Compliance: Meets the requirements of USEPA Method 180.1

Range:
Turbidity: 0-10000NTU
Color: 0-500CU
Turbidity:
(1) 0-1000NTU: 0.01NTU or ±2% of reading; (2) 1000-4000NTU: ±5% of reading; (3) 4000-10000NTU: ±10% of reading.
Chroma:
(1) 0-30CU: ±2CU; (2) 0-500CU: ±5CU
Resolution:
Turbidity: 0.001NTU
Chroma: 1CU
Ratio measurement function: Yes
Minimum sampling volume: 20mL
Measurement mode: NTU, NEP, EBC, ABS, T%, chromaticity unit, user-defined unit
Reproducibility: ±1% of reading or 0.01NTU
Power supply: 230V, 50/60Hz
Operating environment: 10~40℃, 90% relative humidity, no condensation at 25℃
Instrument weight: 3.43kg


American Hach Laboratory Turbidimeter 2100AN Ordering Guide
The standard configuration of the 2100AN laboratory turbidity meter includes: a 2100AN laboratory turbidity meter host, 6 sample cells, StablCal primary standard solution in a sealed bottle, silicone oil, user manual, etc.
47001-02 2100AN laboratory turbidity meter and related accessories


American Hach Laboratory Turbidimeter 2100AN Optional Accessories
20849-00 Sample Cells, Six/Set
26595-05 StablCal Primary Standard in Sealed Vial
1269-36 Silicone Oil, 15mL
47076-00 Sample Cell Wipes
30312-00 USEPA Approved Colorimetric Filters
43975-00 Sample Degasser
43975-10 Sample Filter and Degasser

       