菜单小图标

Esky Purify

Service Line:86-755-27799805
Airborne bacteria sampler
Products

Products
TSI 9510-BD Airborne Bacteria Sampler

TSI 9510-BD Airborne Bacteria Sampler

BIOTRAK Real-time Airborne Bacteria Particle Counter 9 510-BD brings best-in-class features and functionality to the exciting new field of real-time airborne bacterial particle detection. BIOTRAK particle counters detect···...
Get a quote →
Details

BIOTRAK Real-time Plankton


Features and advantages

  • Particle size range 0.5 to 25 μm

  • Up to six channels can measure the total particle count and floating bacterial particle count at the same time

  • Patented laser-induced fluorescence technology determines particle activity

  • Integrated particle collection filter for offline culture analysis

  • Complies with all ISO 21501-4 specifications


  • 1.0 CFM (28.3 L/min) sampling flow

  • Has all the functions of OPC particle counter

    < /li>

  • Intuitive icon-operated touchscreen user interface

  • Menu-based storage and sampling data playback

  • Can generate ISO-14644-1, EU GMP Annex 1, FS209E compliance reports

  • 10,000 sample data storage, 999 locations

  • Ethernet and USB output

  • Can be operated independently or integrated into online monitoring system

  • Displays up to three environmental parameters

  • Stainless steel housing


Technical parameters


Particle size range0.5 - 25 μm
particle size channel0.5, 0.7, 1.0, 3.0, 5.0, 10 μm
Particle size resolution< 15% @ 0.5mm (ISO 21501-4 compliant)
Counting efficiency50% for 0.5mm, 100% for particle size greater than 0.75mm (in accordance with ISO 21501-4 and JIS)
Planktonic bacteria detection2 fluorescence channels and 1 particle size channel to determine
Sampling collectionIntegrated 37mm filter collector
Concentration limitWhen the pressure is greater than 820,000/ft³, the maximum loss is 10%
Zeroing
traffic1.0 CFM (28.3 L/min) ± 5%
CorrectionUsing TSI's NIST-traceable calibration system
Correction frequencyRecommended once a year
Meet standardsISO 21501-4, CE, JIS B9921
Hardware
Total particle detection light source660nm diode laser light source for particle size detection
Light source for detecting floating bacteria particles405nm diode laser light source for laser-induced fluorescence particle activity detection
Flow controlElectronic automatic closed loop
Audible warningBuilt-in, >85dB at 1 meter (adjustable)
External alarm relayNormally open contact closure, rated 0 - 60v AC/DC, 1.5A peak, 0.5A continuous. Alarm output rated 60v isolated. Relay contacts close under user configurable alarm conditions.
ExhaustBuilt-in HEPA filter
Vacuum sourceBuilt-in pump
Alarm outputDry contact, closed when alarmed
DisplayVGA 5.7-in. 14.5-cm HD touch screen
PrinterOptional built-in thermal printer
Dimensions (H x L x W)19 in. x 10.5 in. x 11.7 in.(48.3 cm x 26.7 cm x 29.7 cm)
weight37 lbs (16.8 kg)
power supply110 to 240VAC, universal power supply
Operating Range41° - 86°F (5° - 30°C),**20% - 85% RH non-condensing***
Operating Altitude0 - 10,000 ft (0 - 3,000 m)
Storage Range32° - 122°F (0° - 50°C), up to 98% RH non-condensing
ShellStainless steel
Shell chemical resistanceIsopropyl alcohol, chlorinated solution, hydrogen peroxide
Environmental sensor interfaceSupport TSI® anemometer, temperature and humidity probe
User Interface and Communication
Sampling ModeManual, Automatic, Buzzer. Cumulative/Difference; Count or Concentration
Sampling Time1 sec to 99 hrs
Sampling frequency1 to 9999 cyclic or continuous
Data storage250 regions 999 positions 10,000 Sample Records
Status IndicatorsFlow, Laser
Alarm LimitsAll channels can be set
LanguageSimplified Chinese, English, Japanese, German, French, Spanish and Italian
SoftwareIncludes:▪ TrakPro™ Lite Secure Software▪ FMS Software (OPC UA Bridge 5SP)Optional:▪ FMS Software (Full Version)
Print outputCan support all language print output
Device IDConfigurable IP address
SafetySecond level password protection
ReportISO 14644-1, EU GMP, and FS209E compliance reports available
Communication ModesManual Data Transfer:▪ Export .xml file to USB drive▪ Transfer to TrakPro™ Lite Secure over Ethernet or USBAutomatic Data Transfer:▪ Transfer to FMS via Ethernet▪ Transfer to external software via OPC UA and FMS
Accessories
Includes accessoriesQuick Start Manual, Power Adapter, Isokinetic Probe, Tripod, Sample Tube, 1/2" Barb Inlet Adapter Zero Filter, Cleaning Swab, USB Cable, Airborne Microbe Collector, Calibration Certificate, Cardboard Instructions for Downloading Manuals and Software
Optional AccessoriesElectronic Filter Scanner, Basic Filter Scanner, TSI® Wind speed probe, temperature and humidity probe, isokinetic probe, sampling tube, hard portable box, printing paper, floating bacteria collector, floating bacteria collection filter, BioTrak® aerosol generator



Application Scope

Cleanroom Certification 
Online Monitoring 
Analysis of the Level of Planktonic Particles 
Technology Improvement 
Operator Training 
Qualification Tools 
Risk Management 
Root Cause Investigation


Back to top
WeChat Official Account

WeChat Account

WeChat Video Account

WeChat Video Account

Address:Floor 4-6, Block 3, Building 1, Jia'an Technology Park, Xin'an Street, Bao'an District, Shenzhen
All Rights Reserved Shenzhen ESKY cleanrooms Technology Co., Ltd.    XML map