TSI 9500 Laser Dust Particle Counter

TSI 9500 Laser Dust Particle Counter

TSI 9500激光尘埃粒子计数器具有一流的功能和特性。对于ISO14644-1和欧盟GMP洁净等级认证所要求的1立方米空气样本仅仅需要10分钟!可以方便在显示器上显示粒子数量,可以用TRAKPRO Lite Secure 软件下载,或使用仪器集成的打印机直接打印。···...
Get a quote →
Details


The TSI 9500 Laser Dust Particle Counter offers best-in-class features and functionality. For ISO14644-1 and EU GMP cleanliness class certification required for a 1 cubic meter air sample takes just 10 minutes! Particle counts can be easily displayed on the display, downloaded using TRAKPRO Lite Secure software, or printed directly using the instrument's integrated printer.The Model 9500 counter is compatible with TSI's precision ventilation probes that measure air speed/temperature/humidity, providing a complete solution for your certification. Used in conjunction with one of the optional sampling hoses up to 0.6 meters (26 inches) in length and an electronic filter scanning probe, it provides a better instrument for cleanroom HEPA filter testing.

TSI 9500 Laser Dust Particle CounterThe TSI 9500 Laser Dust Particle Counter generates ISO14644-1, EU EUGMP Annex 1, and FS2O9E compliant, downloadable or printable pass/fail reports via the integrated printer and TRAKPRO Lite Secure software. The particle counter's versatile configuration allows for easy storage and uploading of data as needed. The product can be used as a stand-alone particle counter or integrated into an online plant monitoring system like TSI's FMS 5. Strict adherence to compliance with ISO 21501-4 standards. Calibration is performed using NIST-traceable PSL microspheres, recognized particle inspection standards, TSI's advanced sifter and condensation particle counters.

 

Featured Benefits

Sampling volume 100L/min (3.53cfm)

Measures six channels of data& lt;/p>

Fully compliant with ISO 21501-4. span>

Data storage: 250 zones, 999 locations and 10,000 samples

Data transfer over USB and Ethernet

Industrial audible and visual alarm

High-definition touch screen, easy-to-use graphic interface, Simplified Chinese

Generates compliance reports for ISO-14644-1, EU GMP Annex1 and FS209E

Through the External certification report output by TRAKPRO Lite Secure software

Allows storage and playback of specific tests

& gt;Displays up to 3 environmental parameters

Stainless steel housing

Light weight 

Stand-alone or integrated into an online monitoring system & lt;/span>

 

Technical parameters

™ lt;td style="word-break: break-all;"> 02: at 0.5μm<15% (in accordance with ISO21501-4)  Long-life Laser Diode< /tr>< ;td>Sampling FrequencyExhaust <  Programmable for different channelsDisplay< /tr>& lt;td> Can be used continuously for more than 3 hours& lt;td>Operating range& lt;td>Included Accessories Electronic Filtration Scanning Probe, Basic Filtration Scanning Probe, TSI Windage Probe, Temperature and Humidity Probe, Spare Battery, Dual Port External Charger, Isobaric Probe, Isobaric Sampling Inlet, Sampling Tubes, Packaging Box
Model TSI- 9500
Particle Size Range 0.5-25μm& lt;/td>
Particle size channel 02:0.5,0.7,1.0,3.0,5.0,10.0 μm (additional channels optional)& lt;/span>
Particle Size Resolution
Counting efficiency 02:0.5μm 50%, greater than 0.5μm. 50% at 0.5μm, 100% at >0.75μm (in accordance with ISO21501-4 and JIS)
 5% loss at >400,000 pcs/ft3
Laser Source
Zero Point Every 5 minutes<1 (in accordance with ISO21501-4 and JISB9921)
Sampling volume 100L/min(3.53cfm)
流量控制 Electronic Auto-Close Loop (Patented Flow Control Technology)
External Pipeline  External piping up to 8 meters
Sampling Mode Manual, Auto, Beep. Totalization/Difference; Count or Concentration
Sampling Time& lt;/td> 1 sec to 99 hrs
Exhaust Sampling Frequency Built-in HEPA Filter Membrane
Power SourcePower SourcePower Source Built-in pump
 Built-in pump
 Communication mode Modbus®RTU via Ethernet or USB Interface
Data storage 10,000 data records including date, time, six channels, flow rate, sample ID, sample flow rate, transfer data via USB or use the TraxProTM software download
Audible Warnings< ;/span> 内置,1米时大于85dB(可调整)
 Low Battery, Flow, Laser
Alarm Output Sensor Point, Off On Alarm
Alarm Limits
Alarm LimitsAlarm Limits VGA  VGA 
Language  Simplified Chinese, English, Japanese, German, French, Spanish, and Italian
软件 Compatible with TrakProTM Lite and FMS5 software
Printer  Built-in thermal printer (no printer optional)
Printout Selectable for all languages
Environmental Sensor Interface Support TSI Probe Models: 960,962,964,966 (Air Flow/Temperature/Humidity) and Temperature-Humidity Probes
Unit No.  Configurable IP address
Security Secondary password protection
& lt;span style="font-size:14px;">Local ID& amp;nbsp;to 999 positions; each 16 characters long
Report<  Provides a comprehensive range of products and services based on ISO14644-1, EU GMP and  amp;nbsp;FS209E pass/fail reports
CalibrationCalibration  Traceable to NIST's TSI Calibration System
Calibration Frequency Recommended at least annually
Volume (Hx Lx W)& nbsp;24.1cmx23cmx23.2cm(excluding isovelocity sampling port)
 6.44 kg (two batteries)
Power 110 to 240VAC, normal power supply
Battery Removable rechargeable lithium battery, 2 battery slots
Battery life
& lt;span style="font-size:14px;">Charging time& amp;nbsp;4 hours (when idle)
Surface Material Stainless Steel
 0-50℃, 98% non-condensing
StandardStandardStandard ISO 21501-4, CE, JIS B9921
Optional Accessories


Application range

Particle testing in clean rooms

Airborne particles Research

Leakage Assessment

Leakage Assessment

Indoor Air Quality Assessment

Filter Performance Test

Filter Performance Test

Filter Performance Test

Cleanliness Evaluation and Pollutant Migration Studies

Back to top
WeChat Official Account

WeChat Account

WeChat Video Account

WeChat Video Account

Address:6th Floor, Building 1, Jia'an Technology Park, No. 2 Longchang Road, Block 67, Xingdong Community, Xin'an Street, Bao'an District, Shenzhen
All Rights Reserved Shenzhen ESKY cleanrooms Technology Co., Ltd    XML map