TSI 9565A Handheld Anemometer is available with a wide range of plug-in probes. Users can choose the most suitable probe from a variety of probes with different functions according to the actual test needs, and simply plug in the probe to perform a variety of tests. These probes can measure air velocity, temperature, relative humidity, CO and CO2. Parameters that can be calculated include air volume, heat flow, turbulence, wet bulb temperature and dew point temperature. Probes can be ordered at any time, with a data sheet and traceable certificate. When calibration is required, only the probe needs to be returned for calibration, as the calibration data is stored in the probe. High level of accuracy, especially at low wind speeds, can display up to 5 test parameters at the same time. Can be used as an anemometer air flow meter High level of accuracy, especially at low wind speeds, can display up to 5 test parameters at the same time, and optional "smart" plug-in probes, including CO2 and vane probes. Large display, manual or continuous data logging, included TRAKPROTM and LogDat2TM software, user-defined test data group names, Bluetooth ® printer support, fast calibration and repair service - just return the probe.
Articulated Probe 966 measures wind speed, temperature and relative humidity
It includes a differential pressure sensor
High-precision wind speed detection
Optional "Smart" plug-in probes, including VOC, CO2 and rotating vane probes
Suitable for up to two K-type alloy thermocouples
Large screen display
Show up to five measurements simultaneously
Instant on-screen information and instructions
Local language program
Direct-reading menus for easy setup and setup
Multiple data logging formats
Bluetooth communication for data transfer or remote query
Supports TrakPro and LogDat2TM download software and USB data cable transmission
9565-P | 9565-X | ||
Wind speed (Pitot tube) | Range | 1.27~78.7m/s | / |
Precision | ±1.5% at 10.16 m/s | ||
Resolution | 0.01m/s | ||
Static pressure/differential pressure | Range | -28.0~+28.0 mmHg,-3735~+3735Pa | / |
Precision | ±1% of reading or ±0.01mmHg, ±1Pa | ||
Resolution | 1 Pa, 0.01mmHg | ||
Atmospheric pressure | Range | 68.93~124.08KPa or 517.15~930.87mmHg | |
Accuracy | 2% of reading | ||
Data storage capacity | Capacity | 26500 data and 100 data groups | |
Collection interval | 1s~1h | ||
Operating temperature | 5~45℃ | ||
Storage temperature | -20~60℃ | ||
Time constant | User defined | ||
Instrument size | 9.7 cm × 21.1 cm × 5.3 cm | ||
Instrument weight (with battery) | 0.36kg | ||
Power supply | Four AA batteries or optional AC adapter |
Wind Speed, Temperature and Humidity Probe | Range | Accuracy | resolution | probe size | |
bend probe | 962 |
0~50m/s -18~93℃ |
±3% of reading, or ± 0.015m/s Take the larger 0.3℃ |
0.01m/s 0.1℃ |
Length 101.6cm Top diameter 7.0mm Base diameter 13.0mm Curved part length 15.2cm Curved part diameter 9.5mm |
966 | 0~50m/s -10~60℃ 0~95%RH | ±3% of reading or ± 0.015m/s, whichever is larger ±0.3℃;±3%RH | 0.01m/s 0.1℃ 0.1%RH | Length 101.6cm Top diameter 7.0mm Base diameter 13.0mm Curved part length 15.2cm Curved part diameter 9.5mm |
|
Straight probe | 960 |
0~50m/s -18~93℃ |
0.01m/s 0.1℃ |
Length 101.6cm Top diameter 7.0mm Base diameter 13.0mm |
|
964 |
0~50m/s -10~60℃ 0~95%RH |
±3% of reading or ± 0.015m/s whichever is greater ±0.3℃;± 3%RH |
0.01m/s 0.1℃ 0.1%RH |
Length 101.6cm Top diameter 7.0mm Base diameter 13.0mm |
|
Impeller wind speed, temperature probe | Range | Accuracy | Resolution | Probe size | |
995 | 0.25~30m/s 0~60℃ | ±1% of reading, or ±0.02m/s;0.1℃ | 0.01m/s 0.1℃ | Impeller diameter 100mm | |
Air quality probe | Range | Accuracy | Resolution | Probe size | |
Air quality probe | 980 |
CO2: 0-5000ppm -10~60℃ 0~95%RH |
±3% of reading or ±50ppm, whichever is greater ±0.3℃;± 3%RH |
1 ppm 0.1℃ 0.1%RH | Length 17.8cm Diameter 1.9cm |
982 | CO: 0-500 ppm CO2: 0-5000 ppm -10~60℃ 0~95%RH | ±3% of reading or ±3ppm ±3% of reading or ±50ppm Take the larger ±0.3℃; ± 3%RH |
0.1ppm 1 ppm 0.1℃ 0.1%RH |
Length 17.8cm Diameter 1.9cm |
|
Surface temperature probe | Range | Accuracy | Resolution | Probe size | |
Surface temperature Probe |
792 | -40~650℃ |
±0.056% of reading or ± 1.1℃ whichever is greater |
0.1℃ | 15cm long |
HVAC test and balance test
Cleanroom Testing
Biological Safety Cabinet and Laboratory Fume Hood Testing
HVAC Commissioning and Troubleshooting
Indoor Air Quality Studies
Thermal Comfort Studies
Ventilation Assessment
Handling Airflow Testing
The 9565 Series are portable, handheld, multi-function ventilation test instruments.
These instruments are available with optional differential pressure sensors and are equipped with a wide range, plug-in probes.
Users can choose the most suitable probe from a variety of probes with different functions according to the actual test needs. Simply plug in the probe to perform a variety of tests. These probes can measure air velocity, temperature, relative humidity, CO and CO2.
Parameters that can be calculated include air volume, heat flow, turbulence, wet bulb temperature and dew point temperature. Probes can be ordered at any time with data sheets and traceable certificates.
When calibration is required, only the probe needs to be returned for calibration, as the calibration data is stored in the probe.
High-level accuracy, especially at low wind speeds, can display up to 5 test parameters simultaneously.
Can be used as an anemometer and air flow meter High-level accuracy, especially at low wind speeds, can display up to 5 test parameters simultaneously, optional "smart" plug-in probes, including CO2 and impeller probes.
Large screen display, manual or continuous data logging, TRAKPROTM and LogDat2TM software included, user-defined test data group names, Bluetooth® printer support
Quick calibration and repair service - just return the probe.
WeChat Account
WeChat Video Account