The Thermo Scientific™ Model 410i Carbon Dioxide Gas Analyzer utilizes advanced NDIR optical filter technology to measure CO2 concentrations in emissions. The Model 410i CO2 Gas Analyzer uses advanced NDIR optical filter technology to measure CO2 concentrations in emissions. The Model 410i continuously monitors carbon dioxide (CO2) in emissions from sources, and provides reports that meet industry standard, direct draw, or dilution sampling method standards, depending on the user's choice.
Description:
This analyzer utilizes advanced non-dispersive infrared spectroscopy (NDIR) with an optical fixed band-pass interference filter and a quantum detector to analyze CO2 concentration within the gas stream. 此外,扩展的运行环境温度范围可以在更宽的浓度范围内提供出色的性能,并且在整个量程范围内保持了很好的线性关系主要功能:
先进 NDIR 技术& lt;/span>
User-selectable reporting capabilities
Extended Ambient Temperature Operating Range
Extended Concentration Range of Outstanding performance over a wider concentration range
Linearity across the entire range
Linearity across the full range
Configurable Oxygen Sensor Module:
The Model 410i Oxygen Sensor with Paramagnetic Sensor Technology offers expanded capabilities in CO2 source monitoring, with the ability to read and report oxygen concentrations (up to 100%) in the sample gas stream. In addition, a programming feature allows the user to correct CO2 readings by the amount of oxygen in the sample gas. Optional O2 concentration can be used as a correction factor. (e.g. CO2 corrected to 6% O2 or any other percentage.)
Ethernet connection for efficient remote access
Large Display and Enhanced User Interface with Editable Shortcuts
Large Display and Enhanced User Interface with Editable Shortcuts
Increased flash memory for more data and user-downloadable software
Increased flash memory for more data and user-downloadable software
Enhanced electronic design optimizes product versatility
Enhanced electronic design optimizes product versatility
Improved Layout for Easier Maintenance of Components
This new design is based on a new, improved layout that allows for easier maintenance of components. lt;/p>
Measurement range Standard: 0-200,500,1000,2000,5000,10000 ppm High range: 0-0.5,1,2,5,10,20,25%
Zero Noise Standard: 0.5 ppm RMS (60 sec. averaging time)
High Range: 20 ppm RMS (60 sec averaging time)
Lowest Detection Limit Standard: 1ppm
High range: 40ppm
Zero-Drift (24 hours)
Standard: ±1.0ppm
High range: ±40ppm
Spanning Drift (24 hours)
Standard: <0.5% readings/24 hours; <1% readings/7 days
High range: <2% reading/7 days

WeChat Account