The Thermo Scientific 5800 online gas chromatograph utilizes the principles of gas chromatography coupled with a flame ionization detector (GC-FID) to instantly monitor not only Total Hydrocarbons (THC) and Non-Methane Hydrocarbons (NMHC) in gaseous environments, but also specific VOCs.
Monitorable items include:
A Non-Methane Hydrocarbons (NMHC)
B Benzenes such as benzene, toluene, ethylbenzene, o-xylene, m-xylene, p-xylene, isopropylbenzene, styrene, etc.
Customized solutions, such as ozone precursor substances (PAMS) and special requirement monitoring substances such as methanol, propanol, etc.
Customizable analytical solutions, including software and hardware
Negative pressure injection design
Negative pressure injection design
View instant/historical trend graph
Independent calibration curves for each analyte
High-and low-frequency calibration curves for each analyte
Automatic switching between high and low range calibration curves
Conforms to national standard methods
Measurement of high temperature samples up to 150℃
Able to analyze non-methane hydrocarbons (NMHC) in less than 1 minute
Analysis Method:Meteorological Chromatography with Flame Ionization Detection
Analysis Method:Meteorological Chromatography with Flame Ionization Detection
Measurement range:0-50ppm/500ppm/5000ppm/50000ppm/500000ppm, for methane
Measurement range:0-50ppm/500ppm/5000ppm/50000ppm, for methane
Accuracy:±1%f.s or 0.1ppm (whichever is better)
Limit of detection:0.05ppm
Reproducibility:±1%f.s or 0.1ppm whichever is better
Reproducibility:±1%f.s or 0.1ppm whichever is better
Zero Drift:±1%f.s/week
Zero Drift:±1%f.s/week
Spanning Point Drift:±1%f.s/week
Analysis Time:1 minute for Non-Methane Hydrocarbons (NMHC)
Sample flow rate:Sample for analysis:600ml/min, sample update rate:3-10L/min. max.™ lt;/p>
Calibration cycle:daily/weekly or customizable
System Alarms:Instrument Failure/Calibration Failure/Detector (FID) Failure
Output:Modbus/Ethernet/RS232/4-20mA/RS485/USB
Sample Temperature:15-150°C,85% RH (non-condensing)
Environmental conditions:Operating temperature:0-45°C,0-85% RH (non-condensing)
Storage Temperature:-20-60℃,0-85% RH (non-condensing)
Required power:AC220V, 50/60Hz, 1.5KW
Dimensions:482mm(W)X567mm(D)X355mm(H)
Weight:45kg
Refining and petrochemical industry
Electronic Semiconductor Industry
Wiring Boards
Third Party Notary Testing Industry
Pharmaceuticals Manufacturing
Rubber/Plastic Products
Coatings and Inks
Automotive Manufacturing and Maintenance
Automotive Manufacturing and Maintenance
Printing and Packaging Printing
Furniture Manufacturing
Surface Coating
Ferrous Metallurgy
WeChat Account
WeChat Video Account