菜单小图标

Esky Purify

Service Line:86-755-27799805
VOC detector
Products

Products
5800 online gas chromatograph

5800 online gas chromatograph

Thermo Scientific 5800 online gas chromatograph, using gas chromatography combined with flame ionization detection principle (GC-FID), can not only monitor total hydrocarbons (THC) and non-methane total hydrocarbons (NMH···...
Get a quote →
Details


The Thermo Scientific 5800 online gas chromatograph utilizes the principles of gas chromatography coupled with a flame ionization detector (GC-FID) to instantly monitor not only Total Hydrocarbons (THC) and Non-Methane Hydrocarbons (NMHC) in gaseous environments, but also specific VOCs.

Monitorable items include:

A Non-Methane Hydrocarbons (NMHC)

B Benzenes such as benzene, toluene, ethylbenzene, o-xylene, m-xylene, p-xylene, isopropylbenzene, styrene, etc.

Customized solutions, such as ozone precursor substances (PAMS) and special requirement monitoring substances such as methanol, propanol, etc.

 

Featured Advantages

Customizable analytical solutions, including software and hardware

Negative pressure injection design

Negative pressure injection design

View instant/historical trend graph

Independent calibration curves for each analyte

High-and low-frequency calibration curves for each analyte

Automatic switching between high and low range calibration curves

Conforms to national standard methods

Measurement of high temperature samples up to 150℃

Able to analyze non-methane hydrocarbons (NMHC) in less than 1 minute


 

Technical Parameters

Analysis Method:Meteorological Chromatography with Flame Ionization Detection 

Analysis Method:Meteorological Chromatography with Flame Ionization Detection 

Measurement range:0-50ppm/500ppm/5000ppm/50000ppm/500000ppm, for methane

Measurement range:0-50ppm/500ppm/5000ppm/50000ppm, for methane

Accuracy:±1%f.s or 0.1ppm (whichever is better)

Limit of detection:0.05ppm

Reproducibility:±1%f.s or 0.1ppm whichever is better

Reproducibility:±1%f.s or 0.1ppm whichever is better

Zero Drift:±1%f.s/week

Zero Drift:±1%f.s/week 

Spanning Point Drift:±1%f.s/week

Analysis Time:1 minute for Non-Methane Hydrocarbons (NMHC)

Sample flow rate:Sample for analysis:600ml/min, sample update rate:3-10L/min. max.™ lt;/p>

Calibration cycle:daily/weekly or customizable

System Alarms:Instrument Failure/Calibration Failure/Detector (FID) Failure

Output:Modbus/Ethernet/RS232/4-20mA/RS485/USB

Sample Temperature:15-150°C,85% RH (non-condensing)

Environmental conditions:Operating temperature:0-45°C,0-85% RH (non-condensing)

Storage Temperature:-20-60℃,0-85% RH (non-condensing)

Required power:AC220V, 50/60Hz, 1.5KW

Dimensions:482mm(W)X567mm(D)X355mm(H)

Weight:45kg

Application

Refining and petrochemical industry

Electronic Semiconductor Industry

Wiring Boards

Third Party Notary Testing Industry

Pharmaceuticals Manufacturing

Rubber/Plastic Products

Coatings and Inks

Automotive Manufacturing and Maintenance

Automotive Manufacturing and Maintenance

Printing and Packaging Printing

Furniture Manufacturing

Surface Coating

Ferrous Metallurgy

 



Back to top
WeChat Official Account

WeChat Account

WeChat Video Account

WeChat Video Account

Address:Floor 4-6, Block 3, Building 1, Jia'an Technology Park, Xin'an Street, Bao'an District, Shenzhen
All Rights Reserved Shenzhen ESKY cleanrooms Technology Co., Ltd.    XML map