It is suitable for environmental monitoring stations, indoor environments, third-party testing agencies, scientific research institutions, semiconductors, new energy, biomedicine and related enterprises for the collection and analysis of volatile organic compounds in gas samples. It is also suitable for the collection and storage of volatile organic samples such as US EPA TO15, TO14, PAMS for a certain period of time, meeting the national standards HJ759-2015, GB/T 37185-2018 on sampling gas chromatography/mass spectrometry (GC/MS) method and the "2019 Monitoring Plan for Volatile Organic Compounds in Ambient Air of Cities at or above the Prefectural Level".
Technical parameters
Specifications: 0.5L/1L/3L/6L/15L tank can be selected according to the volume of sampled gas
Flow range: 0.12ml/min-400ml/min
Material: SUS316 stainless steel
Flow stability: 24h≤±1%
Excellent inertness, for highly active sulfur compounds, the analysis reproducibility reaches 99% after 30 days of storage
Inner wall treatment: using advanced electropolishing treatment tank or silanization (Silonite) treatment tank
Inner wall treatment: using advanced electropolishing treatment tank or silanization (Silonite) treatment tank
Maximum pressure resistance: 40psi
Using non-powered sampling, more suitable for field sampling
Performance characteristics
1 Ultra-high inert surface treatment technology
The inner wall adopts innovative ultra-high inert surface treatment technology (chemical vapor coating) and ultrasonic process. The tank has no adsorption to VOC, ensuring sample stability and recovery rate; ppb level sulfur, nitrogen compounds and polar (aldehydes, alcohols, esters, ketones, ethers, etc.) and non-polar compounds can also be easily and non-destructively collected and stored for a long period of time..
2 Strong compatibility
Compatible with all samplers, sampling tank cleaning systems, gas distribution systems and pre-concentrator processing systems on the market, The sampling tank and valve are made of stainless steel, which is durable and can adapt to harsh field use environments.
3 Good air tightness
withNitrogen is pressurized to 30psi, measure and record the initial pressure, then close the sampling tank valve, open the valve after 24 hours, test and record its pressure. The pressure in the tank should not drop by more than 2psi after 24 hours, and the vacuum pump can achieve a vacuum degree below 50mtorr.
4 Diaphragm valve
Diaphragm valve, lined with isolation diaphragm, no filler, maximum pressure resistance 250psig; temperature: 200℃, dead volume: <5µl, internal volume: 150ul; ultra-long and durable design to prevent damage to the slipping thread due to excessive force and affect the air tightness, effective sealing opening and closing times ≥15000 times.
5 Optional pressure gauge head