TSI 8533Portable Laser Dust Detector can simultaneously measure the mass concentration distribution of 5 different particle sizes, corresponding to PM1, PM2.5, respirable dust (RSP), PM10 and total PM (<15μm). The new graphical user interface and color touch screen allow you to quickly set up. The display is clear and easy to read. It shows mass concentration, graphical data and other statistical data in real time. It can also display the status of the instrument's filter, laser and flow, etc.
+ Provides a 37mm sampling filter box for easy on-site calibration
+ Automatic zero adjustment module (optional) to minimize the impact of zero drift
+ STEL alarm function can track 15-min average mass concentration when in hazardous waste sites
+ Standard and advanced calibration capabilities. Includes Photometer Calibration Factor (PCF) and Particle Size Calibration Factor (SCF)
model | TSI 8533/8533EP |
Sensor Type | 90° Light Scattering |
Aerosol Concentration Range | 0.001-150 mg/m3 (calibrated according to ISO12103-1, A1 test dust inhalable fraction) |
Resolution | ± 0.1% reading, or 0.001 mg/m3 , whichever is greater |
Zero stability | 10 second time constant, 24 hours, ±0.001 mg/m3 |
Particle size range | 0.1 ~15μm |
traffic | 3.0 L/min |
Temperature coefficient | Approximately +0.001 mg/m3 per °C (temperature deviation relative to the last zero adjustment) |
Operating temperature | 0 to 50℃ |
storage temperature | -20 to 60℃ |
Operating Humidity | 0 to 95% relative humidity, non-condensing |
Time Constant | User adjustable, 1 to 60 seconds |
Data collection | Data points; 5MB memory (>60,000) once per minute, can be sampled for 45 days) Collection interval; adjustable from 1 second to 1 hour |
Communication interface | USB, Ethernet, USB |
Dimensions (HWD) | 13.5x21.6x22.4 cm,12.5x12.1x31.6 cm |
Weight | 2.0kg including 1 battery, 1.5kg including battery |
Power Supply | AC adapter (standard) or rechargeable battery |
Analog Output | Output voltage: 0~5VDC or 4~20mA user adjustable |
Alarm output | Buzzer or relay: non-latching, MOSFET solid state (polarized) analog switch connector: 4-pin Mini-DIN, buzzer |
Display screen | 5.7 in, VGA color touch screen, 3.5 in, VGA color touch screen |
Weighing sampling | 8533 Replaceable 37mm filter box (provided by user) |
· Industrial/Occupational Health Survey
· Indoor air quality research
· Outdoor environment monitoring
· Baseline trend analysis and screening
· Engineering Control Assessment
·Remote monitoring
· Process monitoring
· Emission monitoring
· Aerosol Survey Research
WeChat Account